![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1455062.1 : T10000A/B - Tape Buckler Problems, FSC5132
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek T10000A Tape Drive - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsThe buckler has a button that connects with the cartrdige leader. These buttons have been coming off on the older design buckler. The typical FSC is 5132. FSC5132 ChangesNone CauseThe buckler has a button that connects with the cartridge leader. These buttons have been coming off on the older design buckler assemblies. SolutionAs the drive goes through the repair process it will get a new design buckler. The old design buckler is black and the new one is white. The older bucklers were supposed to get 150,000 loads before failing but they may not last that long. If you see one or more FSCs that indicate a buckler issue then the button is probably missing. The tape may or may not unload depending on when the button came out. Attachments This solution has no attachment |
||||||||||||||||||
|