Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1452085.1
Update Date:2015-05-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1452085.1 :   ODA patchset 2.5 : What is the difference between using ODA 2.5.0.0.0 and 2.5.5.0.0? Which should I use?  


Related Items
  • Oracle Database Appliance
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Database Appliance>DB: ODA_EST
  •  


ODA X2-3 ONLY supports 2.5.5.0.0 however the original ODA V1 ONLY supports 2.5.0.0.0 - these are not inter-changable

In this Document
Symptoms
Changes
Cause
Solution
References


Applies to:

Oracle Database Appliance - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
ODA - (Oracle Database Appliance)

Symptoms

Scenario #1

There are two different 2.5 ODA patchsets available for download:

  • 2.5.0.0.0 
  • 2.5.5.0.0.

Which one of the above patches should I use?
Do I apply 2.5.5.0 on top of 2.5.0.0? 

 

Scenario #2

I am seeing one of the following Problems attempting to install patchset or iso for ODA 2.5

  • Boot problem after image and attempted deployment
  • Unable to boot ODA from ILOM using redirect

 

Changes

 Just now moving to ODA version 2.5

Cause

Scenario #1

ODA  V1 can only uses the 2.5.0.0.0 patchset
ODA  3-2 can only use the 2.5.5.0.0 Patchset 

2.5.5 is not an upgrade to 2.5


Scenario #2

I you apply the wrong patchset  on the wrong ODA HW version you will not be able to successfully upgrade, deploy or patch the ODA
 

Solution


This problem requires the following Unique ODA Factors

  • X3-2 vs V1
  • ODA version 2.5.x 
You should never install 2.5 on X4-2 - it was never tested or supported as X4-2 was released much later (2.7 and higher)

The unique patch numbering for the ODA of x.5.0 vs. x.5.5 only happened for this single patchset level
As of 2.6 and higher you use the same single patch for any HW version 

Downloads of the current 2.5x version of ODA were based on the specific Hardware used: Specifically

  The newest HW release of ODA X2-3 only supports  2.5.5.0.0  -- note the  2.5.5.0.0  << 5.5

                   The original ODA V1    only supports  2.5.0.0.0   -- note the 2.5.0.0.0    << 5.0

 

Bug 16672769 - iso image 2.5.5.0 can be installed on oda v1 and no warning is generated

 

Comment:  It is possible to download the incorrect version of ODA if you only review the first two-digits of the patch which match at 2.5.x.x.x

  • ODA 2.5.5 (X3-2)         -- this is Version 2 which uses 3 (or 4) separate Physical components
  • ODA 2.5 (X4370m2)    -- Version (V1) is the original self-contained single physical ODA unit
       

After downloading and apply ODA 2.5.5 on a V1 ODA you receive no errors or warnings but the installation fails
this can happen from ILOM, after install but fails during deployment and variations during the installation process

The failure usually generates no warning

There is only one solution if you are applying 2.5.x: Apply the correct ODA patchset level based on V1 or X3-2 HW for 2.5

We are in the process of creating a script to provide warnings for those who have downloaded the incorrect version of 2.5.5. and attempted to apply on ODA V1
Likewise, you cannot apply 2.5.0.0.0 on ODA X3-2

Comment: Please review download and confirm version numbers and associated patches to make sure the proper versions are used for the proper HW

ODA version       ODA HW        Component HW Count      Release Date      

2.5.5.0.0                 X3-2            Three (or 4) pieces            03/2013
2.5.0.0.0          X4370M2            One (selfcontained)           11/2011

  

 Bug 16672769 - iso image 2.5.5.0 can be installed on oda v1 and no warning is generated.

 

WORKAROUND
===========

Skip ODA version 2.5x and apply 2.10 or higher

References

<NOTE:888888.1> - Oracle Database Appliance - 12.1.2 and 2.X Supported ODA Versions & Known Issues
<BUG:16672769> - ISO IMAGE 2.5.5.0 CAN BE INSTALLED ON ODA V1 AND NO WARNING IS GENERATED.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback