Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1450439.1
Update Date:2015-06-09
Keywords:

Solution Type  Problem Resolution Sure

Solution  1450439.1 :   Exadata Cell Server ILOM Reported "OutOfMemory" Errors/Warnings  


Related Items
  • Exadata Database Machine X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: EXADATA
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-5534504271>

Applies to:

Exadata Database Machine X2-2 Hardware - Version All Versions and later
Information in this document applies to any platform.
***Checked for relevance on 27-Jan-2014***

Symptoms

Storage Cell iLOM randomly reboots due to the reported error "Out Of Memory".

Changes

 Recently upgraded to the software version 11.2.2.4.2, and Lights Out version shows (iLOM version) 3.0.16.10 r65138

Cause

This is due to abug with iLOM version in 11.2.2.4.2

CR 7121350: "Exadata X2-2, Service Processor restarted due to Out-Of-Memory condition".

The behavior does not in any way adversely affect the performance of the platform.

Solution

Restarting the SP periodically will help workarounding this issue.

On availability of the next firmware image, upgrade at the earliest convenience.

References

<BUG:7121350> - JAVA.LANG.OUTOFMEMORYERROR AGAIN IN ECX_STANDARD.GETXML AFTER 6952929

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.