Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1447108.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1447108.1 :   T10000A/B/C - FSC3D50 Temp Errors  


Related Items
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential information for Service Personnel

Applies to:

Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
Sun StorageTek T10000A Tape Drive - Version Not Applicable and later
StorageTek T10000C Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

3D50 Temp Errors seen in SPLAT tool or in the event logs.
FSC3D50

Changes

None.

Cause

3D50 temps are informational events that get logged indicating a degraded condition in the drive. 

Solution

3D50 Temp errors indicate a degraded condition in read/write system of the drive. They can cause the drive to request cleaning.  If enough of them occur on a single mount, they can cause the drive to put the tape in "Read Only" status for the remainder of the mount.

These types of errors may be seen in the event logs. The events by themselves do not indicate a need for drive replacement. If the drive is not at T10000A/B code version Rj46.x09 or higher (released code 1.48.x05 is preferred), there could be many of these failures which could cause excessive cleaning of the drive..



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.