![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1447108.1 : T10000A/B/C - FSC3D50 Temp Errors
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable and laterSun StorageTek T10000A Tape Drive - Version Not Applicable and later StorageTek T10000C Tape Drive - Version Not Applicable and later Information in this document applies to any platform. Symptoms3D50 Temp Errors seen in SPLAT tool or in the event logs. ChangesNone. Cause3D50 temps are informational events that get logged indicating a degraded condition in the drive. Solution3D50 Temp errors indicate a degraded condition in read/write system of the drive. They can cause the drive to request cleaning. If enough of them occur on a single mount, they can cause the drive to put the tape in "Read Only" status for the remainder of the mount. Attachments This solution has no attachment |
||||||||||||||||||
|