![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1426773.1 : Brocade 8GB and 16GB "Mod_Inv Speed Mismatch / Incompatible SFP"
In this Document
Created from <SR 3-5388450071> Applies to:Brocade 300 Switch - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk/Tape Storage Area Networks
When trying to establish an 8GB link on an Brocade 8GB capable Switch, you might detect the following error message: "Mod_Inv - Speed Mismatch / Incompatible SFP" Index Port Address Media Speed State Proto
============================================== 0 0 010000 id N4 No_Light FC 1 1 010100 id N4 No_Light FC 2 2 010200 id N4 No_Light FC 3 3 010300 id N8 Mod_Inv FC "Speed Mismatch / Incompatible SFP" 4 4 010400 id N8 Mod_Inv FC "Speed Mismatch / Incompatible SFP" 5 5 010500 id N4 No_Light FC 6 6 010600 id N8 Mod_Inv FC "Speed Mismatch / Incompatible SFP" 7 7 010700 id N8 Mod_Inv FC "Speed Mismatch / Incompatible SFP"
42 42 012a00 id N16 Mod_Inv FC "Speed Mismatch / Incompatible SFP"
============= Port 42: ============= Identifier: 3 SFP Connector: 7 LC Transceiver: 8001101200000000 10_Gbps SM lw Long_dist Encoding: 6 64B66B Baud Rate: 105 (units 100 megabaud) Length 9u: 10 (units km) Length 9u: 100 (units 100 meters) Length 50u: 0 (units 10 meters) Length 62.5u:0 (units 10 meters) Length Cu: 0 (units 1 meter) Vendor Name: BROCADE Vendor OUI: 00:05:1e Vendor PN: 57-1000115-01 Vendor Rev: A Wavelength: 1310 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 0 BR Min: 0 Serial No: KDA112284000781 Date Code: 120712 DD Type: 0x68 Enh Options: 0xf0 Status/Ctrl: 0x82 Alarm flags[0,1] = 0x0, 0x40 Warn Flags[0,1] = 0x0, 0x40 Alarm Warn low high low high Temperature: 50 Centigrade -5 90 0 85 Current: 0.000 mAmps 10.000 95.000 12.000 80.000 Voltage: 3304.8 mVolts 2970.0 3630.0 3134.9 3465.0 RX Power: -19.3 dBm (11.8 uW) 14.5 uW 2238.7 uW 36.3 uW 1122.0 uW TX Power: -inf dBm (0.0 uW)60.3 uW 2238.7 uW 151.4 uW 1122.0 uW
CauseThis is caused by the usage of non brocade branded SFP modules. Any NON Brocade branded SFP in an 8GB FC switch will display "Mod_Inv" (Module Invalid) output in switchshow.
On the new 16GB switch 6510, and incorrect replacement or SFP insertion could cause the same error, see doc
SolutionFor a Brocade 8GB capable Switch ( for example Brocade 300) you need to install the following SFP: 8G SWL 57-1000012-01 from Brocade.
For the 16GB capable switches, From "Fabric OS Administrator’s Guide 53-1002446-01" page 373,
Attachments This solution has no attachment |
||||||||||||||||||
|