1413487.1
:
SL500 : Operator Panel Not Working { LCD TSOP }
Related Items |
- Sun StorageTek SL500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Oracle Support personnel
Created from <SR 3-5178749854>
Applies to:
Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
SL500 Op Panel is blank and does not power on.
Error recorded in Event Logs:
----
2012-01-20T06:34:12.503, 0.0.0.0.0, 000, OpPanel, , config, 0000, 0000, "LCD firmware is out of date - Updating"
2012-01-20T06:34:24.542, 0.0.0.0.0, 000, OpPanel, , config, 0000, 0000, "Failed to access LCD monitor program"
----
Cause
Any of the Faulty Parts listed below can cause this :
LCD Panel / LCD Power & Signal Cables / RLM
Solution
Below approach is suggested in isolating the faulty component :
1. Power Cycle of SL500 would fix any temporary problems.
2. Update the Library FW to latest.
3. FE need to inspect below are seated correctly at both ends :
- RLM- OP Panel Signal Cable
- RLM -OP Panel Power Cable
4. Replace the LCD Panel.
5. Replace below cables :
- 419653601 [F] CBL ASSY,RLM-OP PNL,PWR
- 419653701 [F] CBL ASSY,RLM-OP PNL,SIG
6. In one of the cases below combined cable has solved the problem.
[single harness instead of 2 seperate signal & power cables]
- 419666801 [F] CBL HARNESS,OP,SL500
7. Next option is to go with a Blank RLM. This is helpful if there is a passive component failure on RLM.
Refer:
8. If nothing works, a programmed RLM is needed.
Refer:
References
<NOTE:1013985.1> - SL500 - Procedure to Order a Programmed Replacement RLM Card
<NOTE:1019641.1> - SL500 - Non Pre-Programmed RLM Card Replacement Procedure