Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1405875.1
Update Date:2017-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1405875.1 :   Sun Storage 7000 Unified Storage System: Unable To Download Latest Firmware Via FTP  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7320
  •  
  • Sun Storage 7720 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7420
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
Symptoms
Cause
Solution
 Implemented Fix
 Workaround:
References


Created from <SR 3-5281120792>

Applies to:

Sun Storage 7210 Unified Storage System - Version Not Applicable and later
Sun Storage 7310 Unified Storage System - Version Not Applicable and later
Sun Storage 7410 Unified Storage System - Version Not Applicable and later
Sun ZFS Storage 7320 - Version Not Applicable and later
Sun ZFS Storage 7420 - Version Not Applicable and later
7000 Appliance OS (Fishworks)
NAS head revision : [2011.1 or later]
BIOS revision : [not dependent]
ILOM revision : [not dependent]
JBODs Model : [not dependent]
CLUSTER related : [not dependent]


Symptoms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community


The upload of a Appliance Kit software release via ftp to a Sun Storage 7000 Unified Storage System fails with timeout errors on the CLI.

Transferred 696M of 703M (99%) ... failed
error: download failed: FTP response timeout

Cause

<Bug: 7070586> "Upgrade image download fails when ftp transfer lasts more than 60 seconds"
The cause for this limitation of the Appliance Kit Software is known and is related to following items
  • This is a known limitation of Curl 7.20.0. 
  • All version of Appliance Kit software of revision 2010.Q3 or before are affected
  • FTP timeouts after file transferred completely (though the download is complete libcurl gets timed out)
Note that this will affect upgrades to any release, if done over a relatively slow network until a software release containing the fix has been installed.

Solution

Implemented Fix

Since 2011.1 uses libcurl 7.21.1 an upgrade to Software release 2011.1 or later will implement a fix for this timeout issue and it should not be observed any longer.

Workaround:

As a workaround it is recommended to use HTTP instead of FTP. With HTTP you have the choice between CLI or BUI for uploading the Appliance Kit Software.

For TSC engineers only:
If customer is not able to use HTTP for what ever reason, on the Wiki pages there is a procedure for manual update of the Sun Storage 7000 Unified Storage System, please refer to

https://stbeehive.oracle.com/teamcollab/wiki/AmberRoadSupport:NAS+fw+upgrade+or+update+thanx+to+solaris+shell

References

<BUG:7070586> - AGILE00206737:NOT SHOWING UNDER THE BOOKMARK LIST EVEN AFTER THE ACTIVITY
<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to collect a supportbundle using the BUI or CLI

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback