![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1397685.1 : Sun Storage 7000 Unified Storage System: nge network interfaces may disappear from the appliance under certain conditions
This document is applicable to 7x10 series unified storage appliances that use nge network interfaces In this Document
Applies to:Sun Storage 7210 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] 7000 Appliance OS (Fishworks) NAS head revision : [before 2010.Q3.3.1] BIOS revision : [not dependent] ILOM revision : [not dependent] JBODs Model : [not dependent] CLUSTER related : [not dependent] SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community
Under certain conditions it is possible for an interface on an nge device to fail to attach to the datalink for the device leading to a faulted interface. Jan 27 01:45:41 appliance nge: [ID 801725 kern.warning] WARNING: nge2: nge_attach: nge_smu_sema() failed
Jan 27 01:47:17 appliance last message repeated 19 times
Jan 27 01:47:18 appliance svc.startd[45]: [ID 652011 daemon.warning] svc:/appliance/kit/network/datalink:nge2: Method "exec /usr/lib/ak/svc/method /akdatalink start" failed with exit status 95.
Jan 27 01:47:18 appliance svc.startd[45]: [ID 748625 daemon.error] appliance/kit/network/datalink:nge2 failed fatally: transitioned to maintenance (see 'svcs -xv' for details) Jan 27 01:47:25 appliance nge: [ID 801725 kern.warning] WARNING: nge2: nge_attach: nge_smu_sema() failed Jan 27 01:47:47 appliance last message repeated 4 times Jan 27 01:47:47 appliance ip: [ID 171694 kern.error] nge2: DL_ATTACH_REQ failed: DL_SYSERR (errno 22) Jan 27 01:47:47 appliance ip: [ID 960278 kern.error] nge2: DL_BIND_REQ failed: DL_OUTSTATE Jan 27 01:47:47 appliance ip: [ID 320251 kern.error] nge2: DL_PHYS_ADDR_REQ failed: DL_OUTSTATE Jan 27 01:47:47 appliance ip: [ID 316886 kern.error] nge2: DL_UNBIND_REQ failed: DL_OUTSTATE Jan 27 01:47:54 appliance svc.startd[45]: [ID 652011 daemon.warning] svc:/appliance/kit/network/interface:ipmp1: Method "exec /usr/lib/ak/svc/method/akinterface start" failed with exit status 95. Jan 27 01:47:54 appliance svc.startd[45]: [ID 748625 daemon.error] appliance/kit/network/interface:ipmp1 failed fatally: transitioned to maintenance (see 'svcs -xv' for details) Jan 27 01:48:32 appliance nge: [ID 801725 kern.warning] WARNING: nge2: nge_attach: nge_smu_sema() failed Also look in the interface SMF service logs for messages like: ifconfig: SIOCSLIFNAME for ip: nge3: Invalid argument
ifconfig: setifflags: SIOCGLIFFLAGS: nge3: no such interface This is likely to be <CR 6860426> nge_smu_sema() is failing under certain conditions CauseThe cause of this problem is a problem with the SMU firmware of the onboard network devices. See <CR 6860426> nge_smu_sema() is failing under certain conditions For further details. SolutionThe nge driver was modified to resolve this problem and the fix is to upgrade the appliance kit version to at least 2010.08.17.3.1 (2010.Q3.3.1) or later.
Back to <Document 1392086.1> Sun Storage 7000 Unified Storage System: How to Troubleshoot Network Problems. References<BUG:6860426> - EXCEPTION ERROR OCCURED WHEN RUNNING SCRIPT XT-BUSREG-01<NOTE:1392086.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot Network Problems Attachments This solution has no attachment |
||||||||||||||||||
|