![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1392207.1 : Pillar Axiom: Brick RAID Preemptive Copyaway May Cause Storage to Go Offline Temporarily
Preemptive copy, also known as Copyaway, detects impending failure of a disk drive, checks RAID status, and if the RAID status is fully redundant and current, will initiate a Copyaway process to the available spare before the impaired drive fails. In this Document
Applies to:Pillar Axiom 500 Storage System - Version Not Applicable to Not Applicable [Release N/A]Pillar Axiom 300 Storage System - Version Not Applicable to Not Applicable [Release N/A] Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsAxiom Brick RAID Preemptive Copy may cause storage to go offline temporarilySynopsisPreemptive Copy is a feature of the Axiom where the data contained on a disk drive within a Brick storage enclosure is proactively copied away if it is determined that the drive has degraded to a point that failure is imminent. The Axiom attempts to copy the data off the drive prior to removing it from the associated RAID array in preparation for replacement. Affected Hardware and Software VersionsThis issue affects all Axiom systems that are on AxiomONE 4.2.0 through 4.2.10 releases. The issue was mitigated beginning 4.2.11 by removing the feature until such time it could be corrected.
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage Pillar Axiom System
ChangesN/A CauseProblemIf, during the process of a Preemptive Copy, also known as Copyaway, the drive continues to degrade (i.e. suffers continued read/write errors), it may cause a condition whereby the RAID LUN's contained on the drive are rendered inaccessible. At that point, the LUN's will be taken offline pending completion of the Preemptive Copy operation. Solution
Solution/WorkaroundThis issue was mitigated in Release 04.02.11 of the Axiom software by disabling the Preemptive Copy feature until a full resolution can be put in place. Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||
|