Solution  1390841.1 :   Brocade 5100 false fan failure indication when only power supply receives input  


Related Items
  • Brocade 5100 Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  
  • _Old GCS Categories>Sun Microsystems>Switches>Brocade
  •  


A Brocade 5100 switch may falsely report a fan failure when only one of its two power supplies is receiving power.

In this Document
Symptoms
Cause
Solution


Created from <SR 3-5111824181>

Applies to:

Brocade 5100 Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Brocade 5100, running Fabric OS v6.1.1a or earlier.


Symptoms

Brocade 5100, running Fabric OS v6.1.1a or earlier, with two fan/power supplies installed and just one connected to external power  because there is either no A/C connection or its power switch is turned off  will incorrectly report the fan (not connected to external power) as faulty.

EM-1034 Fan <unit num> set to faulty, rc=20006.


Cause


When two combination Fan/Power Supply units are inserted into the Brocade 5100 and one is not supplying power (i.e. there is no A/C connection or the power switch is turned off), the fan (still) receives power internally from the alternate fan/power supply.

Unfortunately, until external power is provided to the fan/power supply, Fabric OS is unable to read its fan tachometer. Essentially, the fan/power supply tachometer will read ZERO on this unit until it is connected to external power and turned on.

This situation leads to Fabric OS falsely reporting the fan/power supply as faulty.

Solution

To avoid this issue, connect the power cord to the fan/power supply and to external power before seating it within the Brocade 5100 and then turn on the fan/power supply’s power switch as soon as possible after it has been fully installed/seated.

A fix for this problem (DEFECT000231909) was introduced to Fabric OS in v6.1.1b, v6.1.2, and v6.2.0; with this change, if the fan/power supply is not receiving external power, without reporting faulty status (as before) the following message is presented:

HIL-1610 Fan/PS unit <unit num> not supplying power, fan speeds not available.Please ensure that the unit has power and the switch is on.