![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1390005.1 : Sun Netra X4270 - Unable to poweron
Server Unable to power . "-->start /SYS" from ILOM give error "start: Not enough available power". Created from <SR 3-5028929617> Applies to:Sun Netra X4270 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsSun Netra X4270 server unable to power on. -> start /SYS
Are you sure you want to start /SYS (y/n)? y start: Not enough available power ChangesThis may infrequently occur when there is a sudden power outage. CauseIn case of power loss, the fault management logic in the service processor of the server marks both PS0 and PS1 as faulty as per the below example: ->show faulty
-- -- /SP/faultmgmt/1 | fru | /SYS/PS0 /SP/faultmgmt/1/ | class | fault.chassis.env.power.loss -- /SP/faultmgmt/2 | fru | /SYS/PS1 /SP/faultmgmt/2/ | class | fault.chassis.env.power.loss -- SolutionClear the fault conditions registered for each power supply using logging into the service processor and issuing the following commands: -->set /SYS/PS0 clear_fault_action=true -->set /SYS/PS1 clear_fault_action=true -->start /SYS Attachments This solution has no attachment |
||||||||||||
|