![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1386892.1 : Sun Blade X6270 - BSOD while trying to load MDT 2010 with 10 Gbe network drivers on Windows (2008 R2)
In this Document
Created from <SR 3-4295939941> Applies to:Sun Blade X6270 M2 Server Module - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsBSOD while trying to load MDT 2010 with 10 Gbe network drivers on Windows (2008 R2). 0x00000124
FRU Device Description : RFEM0 (LUN 0, ID 128)
Board Product : SUN DUAL 10GBE PCIE 2.0 FEM Board Serial : 0201XR Board Part Number : 375-3648-02 Board Extra : 50 Board Extra : x4871a-z/4871a-z FRU Device Description : NEM0 (LUN 0, ID 241) Board Product : SUN BLADE 6000 ETHERNET SWITCHED NEM 24P 10GE Board Serial : 1005LCB-1039RW001M Board Part Number : 541-3770-02 Board Extra : SAS 5.3.2.0 FRU Device Description : NEM1 (LUN 0, ID 242) Board Product : SUN BLADE 6000 ETHERNET SWITCHED NEM 24P 10GE Board Serial : 1005LCB-1039RW0020 Board Part Number : 541-3770-02 Board Extra : SAS 5.3.2.0
Cause
SolutionThis issue is resolved by using the latest driver from the Intel PROXGB\Winx64\NDIS62\WinPE