Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1380045.1
Update Date:2018-01-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1380045.1 :   Sun Storage 7000 Unified Storage System: Resilver did not start after replacing a failed disk  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-4891865851>

Applies to:

Sun ZFS Storage 7320 - Version All Versions and later
Sun ZFS Storage 7420 - Version All Versions and later
Sun Storage 7210 Unified Storage System - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun Storage 7410 Unified Storage System - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

Failed/faulted disk was replaced

After replacement of the faulted disk, the disk resilver operation did not start.

The spare drives will stay "in use".


Multiple replacements over the last 2 months did not trigger a resilver back to the newly-inserted disk.

 

Cause

Known issue.

 

Solution

 

Recommended action for the customer:

You will need to engage Oracle Support, by opening a Service Request, so that Oracle Support Services can provide confirmation of this issue and then carry out the appropriate activities to resolve the issue.

 

For resolution procedure, consult the following procedure on the NAS Internal wiki:

     https://stbeehive.oracle.com/teamcollab/wiki/AmberRoadSupport:After+replacing+a+data+disk+-+resilver+is+not+starting

    See also  -  Bug 18123332 (2013.1 physical replacement of disk failed to trigger vdev replacement)

 