![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1374799.1 : Sun Storage 7000 Unified Storage System: FMD-8000-4M/FMD-8000-6U reported in SNMP traps 30 days after HW fault events
SNMP traps reporting events FMD-8000-4M & FMD-8000-6U can trigger alerts on third party monitoring software. In this Document
Applies to:Sun Storage 7310 Unified Storage System - Version All Versions and laterSun ZFS Storage 7120 - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun Storage 7110 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsSNMP traps received by third party monitoring agents with the following event types -
ChangesHardware replacements that occurred within 30 days of the first fault event on the hardware.
CauseFMD will continue to track this fault event for 30 days from the initial fault event even after the hardware has been replaced.
SolutionIf you receive the FMA event codes above without any other corresponding FMA faults and the uuid's match for both FMD-8000-4M & FMD-8000-6U events please check the following from the BUI: Maintenance > Problems
1. Look for any current 'Active Problems'
Maintenance > Logs > Faults
for a hardware failure event that occurred 30 days before the FMD-8000-4M / FMD-8000-6U SNMP events.
If there is an event within 30 days before the listed SNMP trap, that has an 'EVENT ID' matching that from the SNMP traps, then confirm that the hardware has been replaced inside the 30 day window from the original fault by: Maintenance > Logs > Alerts
Also check that all hardware currently reports as healthy.
Attachments This solution has no attachment |
||||||||||||||||||
|