Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1374749.1
Update Date:2018-05-21
Keywords:

Solution Type  Problem Resolution Sure

Solution  1374749.1 :   V2X/VSM FSC7464 IXB has detected a bad battery during a battery integrity test.  


Related Items
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  
  • _Old GCS Categories>Announcements>All Product Lines>Support Systems
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Sun StorageTek VSM5 System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SR is created due to ATR from the V2X/VSM issuing FSC7464  IXB has detected a bad battery during a battery integrity test.

Cause

IXB has detected a bad battery during a battery integrity test.

Solution

Download basefiles if none are available in the ATR SR.  Review for the part that was found broken.  Review the V2X/VSM for the part that should show as fenced.  Have that part replaced

References

<NOTE:1306528.1> - How to Remove and Replace a VSM Battery:ATR:903:4
<NOTE:1504079.1> - VSM StorageTek VSM / Bad Battery

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback