Solution Type  Problem Resolution Sure

Solution  1370297.1 :   Brocade licenseadd errors with "I/O error occurred or license DB might be corrupted"  


Related Items
  • Brocade 5300 Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  
  • _Old GCS Categories>Sun Microsystems>Switches>Brocade
  •  


Brocade switch command 'licenseadd' fails with "I/O error occurred or license DB might be corrupted"

In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: seems applicable
Created from <SR 3-4777401616>

Applies to:

Brocade 5300 Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms


Attempting to perform a licenseadd command may fail with "I/O error occurred or license DB might be corrupted". This may be on an installed switch or during a switch replacement where the transferred licenses are being added to the new switch.


Cause


Brocade DEFECT000233165 or one of the other license DB corrupt issues (DEFECT000231935) may apply. These are resolved in FOS 6.2.0 (or higher). If the switch previously had lower firmware than 6.2.0 installed it is possible that its license DB was corrupted during that time.

Solution



The license DB on the switch is not recoverable and the switch needs to be replaced.