Asset ID: |
1-72-1369718.1 |
Update Date: | 2017-04-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1369718.1
:
MB/SC Failure on Sun Fire V240/V440
Related Items |
- Sun Fire V240 Server
- Sun Fire V440 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
- _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
|
In this Document
Created from <SR 3-4251622347>
Applies to:
Sun Fire V240 Server - Version Not Applicable and later
Sun Fire V440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
MB/SC failure has been reported by prtdiag with a message similar to this:
-------------------------
Fru Operational Status:
-------------------------
Location Status
-------------------------
MB/SC faulty
Cause
An error in the SC is detected by the system, and CPUs appear to work properly
CPUstat
Brd CPU Modl Run Ecach CPU CPU CPU CPU CPU online
Nr. Nr. Nr. Mhz MB Impl. Mask Die Amb Stat since
-------------+------+------+------+------+--------+------+-----+-----+--------+-------------------
MB/P0 0 1002 1MB US-IIIi 2.4 - - on-line 07/24/11 16:56:07.
MB/P1 1 1002 1MB US-IIIi 2.4 - - on-line 07/24/11 16:56:38.
However there is still an error message regarding SC:
# /usr/platform/SUNW,Sun-Fire-V240/sbin> ./scadm status
scadm: unable to send data to SC
Solution
1.- Update the Flash Prom and the OBP by applying the latest patch available and then reboot the system
2.- This issue can also be resolved by soft soft reset from the ALOM shell.
sc> resetsc
REFERENCE:
Sun Fire V210 / V240 Patches (Doc ID 1337701.1)
Sun Fire V440 Firmware & Patches (Doc ID 1336234.1)
Attachments
This solution has no attachment