![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1363330.1 : Sun Storage 7000 Unified Storage System: Low throughput during NDMP tape cloning
In this Document
Created from <SR 3-3824904291> Applies to:Sun Storage 7210 Unified Storage System - Version All Versions and laterSun Storage 7110 Unified Storage System - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsSlow NDMP tape cloning in ZFS Unified Storage appliance. NDMP tape cloning to a locally attached tape drives can only achieve around 6MB/sec Normal NDMP backup can achieved much higher around 75MB/sec range. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community
CauseNDMP Tape Cloning Performance problems exist in pre 2011.x appliance NDMP code. Performance improvements to use larger mover record size, removing timeout delay and adding multi-thread capability are being planned. The NDMP Tape Cloning performance can be checked in a similar manner to the following. In the following example, the Data Management Application is running Networker 7.6.1 with Ultrium-5 tape devices connected directly to ZFS Unified Storage appliance. DMA can be any certified platform for ZFS Unified Storage appliance.
Networker nsrndmp_clone run in debug mode: # nsrndmp_clone -vvvv -b'Monthly NDMP Clone' -S 2984830673
... 77398:nsrndmp_clone: NDMP Cloning started ... 67140:nsrndmp_clone: Open the source tape device : /dev/rmt/0n 69700:nsrndmp_clone: record size is set to 60 KB 67141:nsrndmp_clone: Open the destination tape device : /dev/rmt/1n 69700:nsrndmp_clone: record size is set to 60 KB /rmt/0n (NDMP)(J) LTO Ultrium-5 E05144L5 2:reading, data /rmt/1n (NDMP)(J) LTO Ultrium-5 E05181L5 1:writing at 5820 KB/s, 408 MB ** less than 6MB/sec **
Alternatively, ndmpstat shows the number of read/write bytes transferred of about 5670 KBytes aksh> confirm shell ndmpstat 2 5
wthr ops file disk tape bytes perf prcnt r w bk rs rd wr rd wr rd wr rd wr bk rs dsk tpe idl 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 2 0 0 0 0 0 0 0 11340 11340 5670 5670 2 2 0 100 0 2 0 0 0 0 0 0 0 11340 11340 5670 5670 2 2 0 100 0 2 0 0 0 0 0 0 0 11340 11340 5670 5670 2 2 0 100 0 2 0 0 0 0 0 0 0 11400 11400 5700 5700 2 2 0 100 0
SolutionUpgrade to Appliance Firmware Release 2011.1.5.0 (or later) or 2013.1.0.1 (or later).