Asset ID: |
1-72-1352585.1 |
Update Date: | 2017-08-07 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1352585.1
:
SL3000/SL8500 - Result Code 1214, "Device not found - deviceName"
Related Items |
- Sun StorageTek SL3000 Modular Library System
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Created from <SR 3-4365367300>
Applies to:
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Checked for relevance on 5-Feb-2013.
Symptoms
RC1214
Result code 1214
It is running FRS_3.0 and only has one tall bot installed.
Device not found - deviceName
Time : 2011-08-12T01:57:38.141
Device Address : 1.0.0.0.0
User : root
Requester : default
Activity : queryFruInfo
Request Id : 231701
Level : error
Result Code : 1214
Text : "Device not found - deviceName"
Parameters : device=1,2,0,1,0
Time : 2011-08-12T01:57:38.942
Device Address : 1.0.0.0.0
User : root
Requester : default
Activity : queryFruInfo
Request Id : 231801
Level : error
Result Code : 1214
Text : "Device not found - deviceName"
Parameters : device=1,3,0,1,0
Time : 2011-08-12T01:57:39.157
Device Address : 1.0.0.0.0
User : root
Requester : default
Activity : queryFruInfo
Request Id : 231901
Level : error
Result Code : 1214
Text : "Device not found - deviceName"
Parameters : device=1,4,0,1,0
Time : 2011-08-19T01:57:19.491
Device Address : 1.0.0.0.0
User : root
Requester : default
Activity : queryFruInfo
Request Id : 390501
Level : error
Result Code : 1214
Text : "Device not found - deviceName"
Parameters : device=1,2,0,1,0
Time : 2011-08-19T01:57:20.169
Device Address : 1.0.0.0.0
User : root
Requester : default
Activity : queryFruInfo
Request Id : 390601
Level : error
Result Code : 1214
Text : "Device not found - deviceName"
Parameters : device=1,3,0,1,0
Cause
SDP Firmware issue. (Service Delivery Platform)
It is SDP connected, it is reporting the wrong library code level.
The library is running 3.0 but the SDP alert says FRS_2.35 (5.21.00).
SDP site unit attempted to query non existing device.
If SDP connected, queries from the SDP can generate library error_1214.
Solution
It is due to a query from SDP and should have no impact.
This is a benign error for SL3000 & SL8500 devices and will be addressed in future SDP agent code.
Attachments
This solution has no attachment