![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1350257.1 : Sun Storage 7000 Unified Storage System: BUI shows " Hot Spare as 'Undefined' "
During a drive resilver, the BUI fails to declare which drive the hot spare is in use for. In this Document
Created from <SR 3-4199004751> Applies to:Sun Storage 7110 Unified Storage System - Version All Versions and laterSun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later Sun Storage 7410 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsWhen a hot spare is in use after a drive failure, the BUI fails to identify which drive the hot spare is in use for and marks it 'undefined' instead ChangesA drive failure will trigger this Cause<BUG: 15600661> SolutionThe bug is fixed in the 2011.1 release
Attachments This solution has no attachment |
||||||||||||||||||||
|