Solution Type  Problem Resolution Sure

Solution  1350257.1 :   Sun Storage 7000 Unified Storage System: BUI shows " Hot Spare as 'Undefined' "  


Related Items
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  


During a drive resilver, the BUI fails to declare which drive the hot spare is in use for.

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-4199004751>

Applies to:

Sun Storage 7110 Unified Storage System - Version All Versions and later
Sun Storage 7210 Unified Storage System - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun Storage 7410 Unified Storage System - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

When a hot spare is in use after a drive failure, the BUI fails to identify which drive the hot spare is in use for and marks it 'undefined' instead

Changes

A drive failure will trigger this

Cause

<BUG: 15600661>

Solution

The bug is fixed in the 2011.1 release

 