![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1350227.1 : VTL - FCP-2 (FCT) is enabled but not supported in Oracle VTL's.
In this Document
Applies to:Sun StorageTek VTL Plus Storage Appliance - Version 1.0 - Build 1323 to 2.0 - Build 1656 [Release 1.0 to 2.0]Sun StorageTek VTL Prime System - Version 1.0 - Build 1813 to 1.1 - Build 2076 [Release 1.0] Oracle Solaris on x86-64 (64-bit) FCP-2 (Fibre Channel Protocol for SCSI, second version) is enabled but not supported in Oracle-Sun VTL's. This creates a problem whereby a Tape Backup application can request FCP-2 usage with a VTL to correct for SAN error anomalies and believe that it is working correctly when, in fact, it is not. This could further create a situation where data is believed to have been written to virtual tape but has not. Also referred to as FCT or FC Tape support (Fibre Channel Tape support) SymptomsLook for SRR_ in the messages log. Below is an example: ChangesChanges to the SAN infrastructure. It is possible that the cause is not actually seen by switch error reporting, and only seen by a Fibre Channel analyzer. CauseFCP-2 (Fibre Channel Protocol for SCSI, second version) is enabled but not supported in Oracle-Sun VTL's. SolutionThe permanent solution is to update to the Get Well Plan for you current build. Please see internal reference document. If you do not have access please contact your local field support organization. Attachments This solution has no attachment |
||||||||||||||||||
|