Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1347238.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1347238.1 :   SLConsole - Change User Failed - Unable to Change Password - Exit Code: 1  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • StorageTek Library Console
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-4190304090>

Applies to:

StorageTek Library Console - Version 4.40 to 4.75 [Release 4.0]
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

When modifying the User password under the SLConsole's User Management tab, the following error
message is displayed:

Modify User account failed
Error: Change User failed - unable to change password - Exit Code: 1

Changes

Change user password in the SLConsole.

Cause

A password with the character "+" is not accepted.

Solution

Enter a new password that does not contain the "+" character.

References

<NOTE:1014164.1> - SL3000/SL8500 - How to Reset Passwords on Library

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.