Asset ID: |
1-72-1343176.1 |
Update Date: | 2017-07-06 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1343176.1
:
V2XF - Host IEA480E message with REFCODE of FSC3FDD
Related Items |
- Sun StorageTek V2X SVA Disk System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
- _Old GCS Categories>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
- _Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
|
V2X subsystem posted a SIM message with FSC 3FDD
In this Document
Applies to:
Sun StorageTek V2X SVA Disk System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
V2X posted SIM message with the following information in it to the host:
IEA480E aaaa,SCU,MODERATE ALERT,MT=2105,SER=ssss-sssss,REFCODE=3FDD-zzzz-zzzz
More detail:
aaaa is the address associated with the SIM message
SER is serial number which is posting the SIM message
REFCODE = Provides data of the event, including the FSC code
Cause
PPRC LINK LOST CONNECTION ON IFC CARD SLOT 12 BOTTOM INTERFACE
Solution
Recovery steps:
NOTE: The V2X is stating the link is down between this V2X and the secondary
unit, not that it has dropped the link.
90% of these events are caused by something external to the subsystem.
1. Attempt to reestablish the link with CESTPATH command for this link.
If successful, monitor for re-occurrence.
2. If the link can not be established, contact the vendor of the network
between the two units.
Contact Oracle to review the status of the V2X that posted the SIM and the
secondary V2X.
Attachments