Asset ID: |
1-72-1339386.1 |
Update Date: | 2018-02-16 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1339386.1
:
V480/V490 POST Memory Failure - Data or Instruction Access Error
Related Categories |
- PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx80
- _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
|
In this Document
Created from <SR 3-4060432401>
Applies to:
Sun Fire V490 Server - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
=== ODM Issue Clarification ===
Memory DIMM module has failed which resuted in server being hung.
=== ODM Issue Verification ===
2:0>WARNING: TEST = Block Memory
2:0>H/W under test = CPU0, All CPU0 Memory
2:0>MSG = Data or Instruction Access Error,
Trap Type 00000000.00000063
Trap PC ffffffff.f0124bb0
Trap Level 00000000.00000001
AFSR 00100002.00000034
AFAR 00000020.4334da90
2:0>END_WARNING
2:0>ERROR: TEST = Block Memory
2:0>H/W under test = CPU2 Bank 0 Dimm 1, J7901 side 1
2:0>Repair Instructions: Replace items in order listed by 'H/W under test' above.
2:0>MSG = DIMM failure Bank 0 DIMM 1 Pin 145
2:0>END_ERROR
Cause
=== ODM Cause Determination ===
DIMM failure
=== ODM Cause Justification ===
2:0>ERROR: TEST = Block Memory
2:0>H/W under test = CPU2 Bank 0 Dimm 1, J7901 side 1
Solution
=== ODM Solution / Action Plan ===
DIMM should be replaced.
After replacement an extended POST should be performed to verify the HW status.
Attachments
This solution has no attachment