Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1338601.1
Update Date:2018-02-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1338601.1 :   Sun Fire V480/V490 Server: Disk failure and diagnosis  


Related Items
  • Sun Fire V490 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx80
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-4052306781>

Applies to:

Sun Fire V490 Server - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms



To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - SPARC Legacy Servers




=== ODM Issue Clarification ===
Sun Fire V490 Server:Internal Disk in maintenance state.


=== ODM Issue Verification ===
*** format errors ***

0. c1t0d0 drive not available
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000011c6e36a68,0



*** Solaris Volume Manager (SVM / SDS) messages ***

d10: Submirror of d0
State: Needs maintenance
Invoke: metareplace d0 c1t0d0s0
Size: 62928384 blocks (30 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s0 0 No Maintenance Yes


d16: Submirror of d6
State: Needs maintenance
Invoke: metareplace d6 c1t0d0s6
Size: 57514752 blocks (27 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s6 0 No Maintenance Yes


d11: Submirror of d1
State: Needs maintenance
Invoke: metareplace d1 c1t0d0s1
Size: 67120896 blocks (32 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s1 0 No Maintenance Yes


d13: Submirror of d3
State: Needs maintenance
Invoke: metareplace d3 c1t0d0s3
Size: 62928384 blocks (30 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s3 0 No Maintenance Yes


d15: Submirror of d5
State: Needs maintenance
Invoke: metareplace d5 c1t0d0s5
Size: 2116608 blocks (1.0 GB)
Stripe 0:
Device Start Block Dbase State Reloc Hot Spare
c1t0d0s5 0 No Maintenance Yes



*** iostat -En of suspect disks ***

c1t0d0 Soft Errors: 0 Hard Errors: 3 Transport Errors: 451538
Vendor: SEAGATE Product: ST314655FSUN146G Revision: 0691 Serial No: 0746S2YSVC
Size: 146.80GB <146800115712 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0


*** messages error summary ***

c1t0d0:

Type: Offline, Quantity: 55353 Last message:
Jul 14 19:22:20 sbprd01 scsi: [ID 107833 kern.warning] WARNING: /pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w21000011c6e36a68,0 (ssd0):
Jul 14 19:22:20 sbprd01 drive offline
Counted for analysis: Yes



suspects
From Automation

===========
device => suspicion level
c1t0d0 => 16

Cause


HDD failure

Solution

To Determine the slot location on this platform can be difficult with multi path drives.  To get more information on how multi-path drives are configured see:

Sun Fire[TM] Servers (V480, V490, V880, V890):Troubleshooting Fibre Channel Drives (Doc ID 1383660.1)


Replace Disk.  Follow the document:

How to Remove and Replace a SunFire V480/V490 Hard Disk Drive (HDD):ATR:1004:0 [Video] (Doc ID 1272665.1)

References

<NOTE:1272665.1> - How to Remove and Replace a SunFire V480/V490 Hard Disk Drive (HDD):ATR:1004:0 [Video]
<NOTE:1383660.1> - Sun Fire[TM] Servers (V480, V490, V880, V890):Troubleshooting Fibre Channel Drives

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.