![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1338039.1 : Sun Storage Common Array Manager reports the alarm "Tray.xx.Drive.yy is at revision "B" baseline version is "A""
In this Document
Created from <SR 3-4034402061> Applies to:Sun Storage 6780 Array - Version Not Applicable and laterSun Storage 2530 Array - Version Not Applicable and later Sun Storage 2530-M2 Array - Version Not Applicable and later Sun Storage 2540 Array - Version Not Applicable and later Sun Storage 2540-M2 Array - Version Not Applicable and later Information in this document applies to any platform. SymptomsSun Storage Common Array Manager (CAM) reports the following alarm code xx.75.42: Description: Tray.xx.Drive.yy is at revision "B" baseline version is "A"
Alarm ID : alarm4
Description: Tray.00.Drive.05 is at revision "0706" baseline version is "0605" Severity : Major Element : ---hidden--- GridCode : 57.75.42 Date : 2011-07-11 12:37:12 CauseThis alarm means that the drive has a firmware (FW) which is at a different level than the one bundled with the CAM baseline. Drive FW cannot be downgraded.
SolutionAs from CAM 6.6 and higher, CAM no longer reports this alarm if a drive has a higher FW than the one bundled with the baseline. Upgrade to the latest release of CAM, refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches. Solution 2: Ignore this alarm. Provided that the drive FW revision is higher than the CAM baseline.
Do you still have questions? You can use My Oracle Support Communities. Communities put you in touch with industry professionals like yourself. They are monitored by Oracle support engineers, so you can expect reliable and correct answers. Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.
Attachments This solution has no attachment |
||||||||||||||||
|