Solution Type Problem Resolution Sure Solution 1334758.1 : Sun Storage 7000 Unified Storage System: Active Directory Machine Accounts Unable To Access Ipc$ Share
Machine accounts in Active Directory are given a "bad password" error when attempting to connect through to the IPS$ share on the 7410. In this Document
Created from <SR 3-2952032901> Applies to:Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7210 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun ZFS Storage 7120 - Version Not Applicable to Not Applicable [Release N/A] 7000 Appliance OS (Fishworks) SymptomsMachine accounts in Active Directory are given a "bad password" error when attempting to connect through to the IPS$ share on the 7000 Unified Storage System. When attempting to access share using a "normal" AD user account everything works fine. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community
CauseSee Bug 15769731 : SUNBT6822262-AK-2011.04.24 WINDOWS MEDIA SERVICE/SQL SERVER CANNOT CONNECT TO CI for details When using "Client push installation functionality" found on SCCM 2007, the problem is seen when the SCCM user (a default SCCM Machine account) tries to access the share and gets a permission denied error. SolutionIssue is fixed in latest ak firmare 2011.1.3.0 [ak-2011.04.24.3.0]. Please upgrade to this version or later. Attachments This solution has no attachment |
||||||||||||||||||
|