Symptoms
Cause
Solution


Created from <SR 3-3860882421>

Applies to:

Sun Enterprise 3500 Server - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Similar messages seen in /var/adm/messages* and prtdiag


=== Issue Verification ===

From prtdiag -v:

========================= Environmental Status =========================
Keyswitch position is in Normal Mode
System Power Status: Redundant
System LED Status: GREEN YELLOW GREEN
WARNING ON ON BLINKING


Fans:
-----
Unit Status
---- ------
Disk FAIL
 

Detected System Faults
======================
Disk Drive Fan failure
        Detected Fri Jun  3 21:37:59 2011
PROM detected failure
        Detected Fri Jun  3 21:37:59 2011
       
       
From /var/adm/messages*
       
Jun  3 12:46:12 xxxx unix: WARNING: Disk Drive fan failure detected

Cause

The E3500 Fan tray that sits below the Disk Drive assembly has failed or is failing.
These Fans provide cooling to the FCAL disks, therefore, the error messages indicate Disk Drive Fan Failure. The Fan Tray is a complete FRU with 3-Fan Assembly.

Solution


=== Action Plan ===

FE on-site must replace the 3-Fan Tray Assembly with part number 540-3566 [F]


Attachments
This solution has no attachment