![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1326200.1 : Sun Storage 7000 Unified Storage System: NDMP tape cloning failed to establish connection.
In this Document
Created from <SR 3-3188763811> Applies to:Sun Storage 7110 Unified Storage System - Version All Versions and laterSun ZFS Storage 7320 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) NAS head revision : not dependent BIOS revision : not dependent ILOM revision : not dependent JBODs Model : not dependent CLUSTER related : not dependent SymptomsOn a Sun Storage 7000 Unified Storage System NDMP backup and restore has been successful, it is not possible to clone a tape, it fails with "Connect error: Connection refused"
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance Community
CauseFor troubleshooting purpose NDMP daemon was started in debug mode and the collected message file contains "connection refused" messages due to a failed forward/reverse IP address resolution on DNS server. Please contact Oracle Support to start the NDMP daemon in debug mode. Debug mode is no longer necesary starting with the 2011.1.1.0 appliance code where ndmp logging is always enabled For procedure to start NDMP in debug mode see "How to Enable NDMP debugging". If you are unable to access this link please contact a member of the NAS Support team.
Mar 21 04:59:15 brain /usr/lib/ndmp/ndmpd[19178]: [ID 702911 daemon.error] Failed to send command to tape: No such file or directory.
3/21 4:59:15 DEBUG: [16][ndmp_open_list_add:1586]:conn: 0x083447c8, dev: /dev/rmt/12n, sid: 12,=lun: 0
3/21 4:59:15 DEBUG: [16][common_tape_open:1371]:Tape is opened fd: 14 3/21 4:59:15 DEBUG: [16][ndmp_process_messages:1308]:no more messages in stream buffer 3/21 4:59:15 DEBUG: [16][nlp_event_rv_set:1279]:rv: 1 3/21 4:59:15 DEBUG: [16][ndmp_process_messages:1200]:reply_expected: FALSE 3/21 4:59:15 DEBUG: [16][ndmp_process_messages:1280]:received request: 0x303 3/21 4:59:15 DEBUG: [16][ndmpd_tape_mtio_v2:396]:ioctl MTIO rc:-1, cmd:1, retry:0, error: 5 3/21 4:59:15 ERROR: [16][ndmpd_tape_mtio_v2:408]:Failed to send command to tape: No such file or directory. 3/21 4:59:15 DEBUG: [16][ndmpd_tape_mtio_v2:409]:ioctl(MTIOCTOP) error: No such file or directory. 3/21 4:59:15 DEBUG: [16][ndmpd_tape_mtio_v2:396]:ioctl MTIO rc:0, cmd:5, retry:0, error: 2 3/21 4:59:17 DEBUG: [17][ndmp_connect_sock_v3:2078]:addr 74.55.25.138:64067 3/21 4:59:18 DEBUG: [17][ndmp_connect_sock_v3:2091]:Connect error: Connection refused 3/21 4:59:18 DEBUG: [17][ndmp_process_messages:1308]:no more messages in stream buffer
42597:nsrndmp_clone: mover connect: failed to establish connection
42803:nsrndmp_clone: Failed to send the MOVER_CONNECT message to the NDMP tape server.
SolutionTo avoid this error and ensure correct operation of the ZFS Storage Appliance, a fully working DNS environment is required which is able to do forward and reverse address resolution for the Appliance.
Back to Document 1387930.1 Sun Storage 7000 Unified Storage System: How to Troubleshoot NDMP issues". References<NOTE:1387930.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot NDMP IssuesAttachments This solution has no attachment |
||||||||||||||||||
|