SL8500 - H-Bot Movement in RIM Corner May Make Clicking Noise
Related Items |
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Partners and Oracle Support personnel
Applies to:
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
H-Bot Movement in RIM Corner May Make Clicking Noise
Cause
A small quantity of RIM rail corner sections were released that have the white plastic rivets retaining the copper strips installed upside down. There is a slight possibility that the rivet can then be hit by the large rollers on the H-Bot making a faint clicking sound. Functional errors have been reported due to this issue.
Solution
The correct orientation of the rivets is to have the smooth rounded part of the rivet on top of the copper strips and the larger, expanded part facing down. The attached pictures show the rivets in the WRONG orientation.
Please inspect all new installations for this condition.
A procedure to inspect and replace these rivets if necessary is attached.