![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1319397.1 : SL8500 - Elevator Tube is Damaged Due to Failed Roller
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsElevator tube damaged by failed roller. CauseRoller on elevator assembly has failed. SolutionIn the event that the elevator tube is damaged by a failed roller, the tube can be rotated to present a smooth surface to the replacement rollers. This should remove the requirement to replace an elevator tube. 419889103 - ROLLER,3/4 OD At this time the 1" roller used on the H-Bots is not available as a FRU. Engineering has decided to have the field replace any H-Bots if any of the 1" rollers (Rail contacting rollers) are defective. Attachments This solution has no attachment |
||||||||||||||||
|