Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1314501.1
Update Date:2017-12-04
Keywords:

Solution Type  Problem Resolution Sure

Solution  1314501.1 :   T6320 Blade not able to see 10Gb Hydra NEM+ port when having wrong release of SP  


Related Items
  • Sun Blade T6320 Server Module
  •  
  • Sun Blade 6000 System
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: SB60xx
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Blade Servers
  •  


T6320 Blade not able to see 10Gb Hydra NEM+ port when having wrong release of SP

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-3243164791>

Applies to:

Sun Blade T6320 Server Module - Version All Versions and later
Sun Blade 6000 System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Customer is having a SunBlade 6000 with 2 "VIRTUALIZED MULTI-FABRIC 10GBE NEM" modules which are currently running fine with X64 blades.
Customer has got a FEM module (X4835A) for the T6320 blade in order to use the 10Gbit ethernet for storage. He installed the FEM module in the blade and rebooted it.

The 10GB-ports are not shown at show-nets (customer is unable to use his nxge interfaces)

Changes

The customer has just installed FEM module (X4835A) which is the supported module for this kind of NEM ("VIRTUALIZED MULTI-FABRIC 10GBE NEM")

Cause

Customer is having a Service Processor with -05 revision
(in the showfru)

/InstallationR[0]/Fru_Path: /SYS/SP
     /InstallationR[0]/Parent_Part_Number: 5101170
     /InstallationR[0]/Parent_Serial_Number: xxxxxx
     /InstallationR[0]/Parent_Dash_Level: 05
     /InstallationR[0]/System_Id: xxxxxxxx-xxxxxxxx

 

As explained in the Sun Blade T63X0 PCIe Pass-Through Fabric Expansion Module User’s Guide:
(...)
501-1170-05 (or earlier) – You must replace the service processor with the latest version.
(...)

This type of requirements are also listed in the notes of the FEM in the Handbook

Solution

- Replace the SP with 501-1170-06 or later
- Apply patch
142151-03  Hardware/PROM: Sun Blade T6320 Server Module motherboard CPLD update for Fabric Expansion Module (FEM)

NOTEs:

  • Installing the Patch 142151-03  (Sun Blade T6320 Server Module motherboard CPLD update for Fabric Expansion Module; FEM) will fail if an older rev ILOM is in the T6320 blade.
  • These older ILOM cards; 501-7822-xx (any revision) and 510-1170-05 (or earlier) will not work with patch 142151-03. Before installing the patch, please check your ILOM rev level by doing:

       -> show SYS/SP or sc> showfru /SYS/SP

  • The T6320 G2 blades do not need this CPLD patch.

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback