Asset ID: |
1-72-1314501.1 |
Update Date: | 2017-12-04 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1314501.1
:
T6320 Blade not able to see 10Gb Hydra NEM+ port when having wrong release of SP
Related Items |
- Sun Blade T6320 Server Module
- Sun Blade 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: SB60xx
- _Old GCS Categories>Sun Microsystems>Servers>Blade Servers
|
T6320 Blade not able to see 10Gb Hydra NEM+ port when having wrong release of SP
In this Document
Created from <SR 3-3243164791>
Applies to:
Sun Blade T6320 Server Module - Version All Versions and later
Sun Blade 6000 System - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Customer is having a SunBlade 6000 with 2 "VIRTUALIZED MULTI-FABRIC 10GBE NEM" modules which are currently running fine with X64 blades.
Customer has got a FEM module (X4835A) for the T6320 blade in order to use the 10Gbit ethernet for storage. He installed the FEM module in the blade and rebooted it.
The 10GB-ports are not shown at show-nets (customer is unable to use his nxge interfaces)
Changes
The customer has just installed FEM module (X4835A) which is the supported module for this kind of NEM ("VIRTUALIZED MULTI-FABRIC 10GBE NEM")
Cause
Customer is having a Service Processor with -05 revision
(in the showfru)
/InstallationR[0]/Fru_Path: /SYS/SP
/InstallationR[0]/Parent_Part_Number: 5101170
/InstallationR[0]/Parent_Serial_Number: xxxxxx
/InstallationR[0]/Parent_Dash_Level: 05
/InstallationR[0]/System_Id: xxxxxxxx-xxxxxxxx
As explained in the Sun Blade T63X0 PCIe Pass-Through Fabric Expansion Module User’s Guide:
(...)
501-1170-05 (or earlier) – You must replace the service processor with the latest version.
(...)
This type of requirements are also listed in the notes of the FEM in the Handbook
Solution
- Replace the SP with 501-1170-06 or later
- Apply patch 142151-03 Hardware/PROM: Sun Blade T6320 Server Module motherboard CPLD update for Fabric Expansion Module (FEM)
NOTEs:
- Installing the Patch 142151-03 (Sun Blade T6320 Server Module motherboard CPLD update for Fabric Expansion Module; FEM) will fail if an older rev ILOM is in the T6320 blade.
- These older ILOM cards; 501-7822-xx (any revision) and 510-1170-05 (or earlier) will not work with patch 142151-03. Before installing the patch, please check your ILOM rev level by doing:
-> show SYS/SP or sc> showfru /SYS/SP
- The T6320 G2 blades do not need this CPLD patch.
Attachments
This solution has no attachment