Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1307170.1
Update Date:2017-09-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1307170.1 :   LTO-4 - Some Drives Are Seen Under Lib Admin at 1GB, Others Are Seen on the Same Switch at 4GB  


Related Items
  • IBM LTO4 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-3189144061>

Applies to:

IBM LTO4 Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Some drives are seen under lib admin at 1GB, others are seen on the same switch at 4GB.
(Library at 3.17.03   Drives at 91VF)

Changes

Recommended to have all drive set with loop_id=126 for soft addressing. Also check the switch port link speed and topology settings.

Port loop_id already set to 126 for all drives, switch ports in auto-neg (same results when forced to 4GB).

Have seen similar issues with switch firmware.

Cause

The Report from lib admin did not show evidence of Hardware errors on the drives..
Customer complained that the drives kept going down under NBU.  More likely drives went down once and did not re-negotiate at 4GB after that with the switch.

Solution

FE unplugged/plugged the fiber cables and PORed the drives.
Drives speed links are now seen at 4GB in L700 Library Admin.
Communication between drives and switch is now optimal.

Customer could have reseated the associated ports on the switch. This might have fixed too.