Asset ID: |
1-72-1282428.1 |
Update Date: | 2017-05-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1282428.1
:
HP LTO-5 - Problem With Routing of Ethernet Cable From Drive to Drive Tray
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Applies to:
HP LTO5 Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
The failure is, "Signal and active LED failure on management port".
Ethernet cable becoming disconnected.
Lose of communication with the drive.
Changes
NA
Cause
Ethernet cable not routed correctly.
There have been a couple of reports of the Ethernet cable that runs from the drive tray to the drive becoming disconnected. It was found that if the cable was bent to the right or left from the rear cover it would vibrate loose.
Part number of the cable is: 418617305
Solution
Check routing of cable.
The solution is to route the Ethernet cable in a U-shape straight from the rear cover and then down to the drive connector. The fiber cables must be under the Ethernet cable as the rear cover is close.
Refer to the attached photos.
Attachments
This solution has no attachment