Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1208953.1
Update Date:2016-02-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1208953.1 :   Sun Storage 7000 Unified Storage System: An unanticipated system error occurred: attempted to return bytes, exceeding maximum of bytes  


Related Items
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Sun Storage 7110 Unified Storage System - Version All Versions and later
Sun Storage 7210 Unified Storage System - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Sun Storage 7410 Unified Storage System - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

BUI or aksh cli operation might fail with the following error

Unanticipated error or software defect
Native message: <function-name> attempted to return <new-max> bytes, exceeding maximum of <current-max> bytes


Cause

This is due to one of the bugs listed below, to identify the relevant bug id match the function-name in the error message.

<BUG: 15593537>  routing.list() Fixed in 2010.Q1
<BUG: 15655768>  dataset.read() Pending release in 2010.Q3
<BUG: 15648192>  iscsit.listInitiators() Fix is being planned

Solution

Upgrade the software if your bug status is fixed released. Otherwise you need to file a  support Service Request (SR) for this issue.

Internal only:
Workaround:
Check if you can reduce content that was being read and the error occurred, or ..
Increase the akd/rpc_rmax size value. `svccfg -s akd setprop akd/rpc_rmax = '<value>'` but has performance implications.
If customer is hitting a new function and is not in the above list, file a RPE CR and update this KA.