Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1114652.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1114652.1 :   LTO4/5 - Power Cycling Drives After Firmware Upgrade When Attached to a Key Management System (KMS)  


Related Items
  • IBM LTO4 Tape Drive
  •  
  • HP LTO5 Tape Drive
  •  
  • HP LTO4 Tape Drive
  •  
  • Oracle Key Manager
  •  
  • IBM LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

HP LTO4 Tape Drive - Version Not Applicable and later
IBM LTO4 Tape Drive - Version Not Applicable and later
HP LTO5 Tape Drive - Version Not Applicable and later
IBM LTO5 Tape Drive - Version Not Applicable and later
Oracle Key Manager - Version 2.0.0 and later
Information in this document applies to any platform.

Symptoms

Load errors and unable to write or read data back.
HP drive could write unencrypted tapes while the customer is unaware.
IBM drives will not configure causing SL Console to mark the drives as unusable.  Customer will loose access to the drives.

Cause

After a drive firmware update in a LTO Gen-4 or Gen-5 drive attached to a Oracle/SUN Key Management System (KMS), a power cycle of the tray is required to ensure the drive and Encryption Adapter are synchronized and the drive is configured by the respective library.

Solution

To power cycle the Tape Drive:
1. Issue a reboot command via SL Console in the SL3000 or SL8500.  A reboot can occur by pulling and re-inserting the drive tray assembly.
2. For SL500,perform the reboot by removing the drive tray assembly for 10 seconds from the library and then re-inserting the assembly back into the library.


- This needs to be done on any level of KMS in service.
- This is only for LTO drives.
- This effects all firmware levels on the Dione or Belesareous card.

No additional fix is coming from IBM.  HP is working on a fix but no ETA at this time.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback