Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1113014.1
Update Date:2014-09-24
Keywords:

Solution Type  Problem Resolution Sure

Solution  1113014.1 :   HALRT-02008: Database node hard disk predictive failure  


Related Items
  • Oracle Exadata Storage Server Software
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  
  • _Old GCS Categories>ST>Server>Engineered Systems>Exadata>Hardware
  •  




In this Document
Symptoms
Cause
 Impact:
Solution
 References:


Applies to:

Oracle Exadata Storage Server Software - Version 11.2.1.3.1 to 11.2.1.3.1 [Release 11.2]
Exadata Database Machine X2-2 Hardware
Information in this document applies to any platform.

Symptoms

An Oracle Exadata ASR alert is generated when a database node disk enters predictive failure status.

Cause

The physical drive is in predictive failure status.

Impact:

None

Solution

Replace this physical drive as soon as possible.

Please see Section 3.2,"Servicing Storage Drive" of Sun Fire X4170, X4270, and X4275 Servers Service Manual for additional information about servicing the disks.

Note: This physical drive is hot-pluggable, which means it can be replaced when power is on.

References:






Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.