![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1101429.1 : Brocade Fabric switch: Unable to save Defined zoning configuration
In this Document
Applies to:Sun Storage SAN Foundation Software - Version 4.0 and laterBrocade 12000 Fabric Switch - Version Not Applicable to Not Applicable [Release N/A] Brocade 200E Switch - Version Not Applicable to Not Applicable [Release N/A] Brocade 24000 Director - Version Not Applicable to Not Applicable [Release N/A] Brocade 3200 Fabric Switch - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. SymptomsAttempts to save the current zoning configuration on a switch fail: switch1:admin> alicreate "myalias","2,10"
switch1:admin> zoneadd "prod","myalias" switch1:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Trans Save failed: Sfc Was Rejected: Remote Switch Unable To Process <----------------FAILURE
CauseSymptomatic messages from supportshow (errDump): 2008/10/30-11:18:24, [RCS-1006], 40334,, INFO, switch1, State 2, Application Zoning AD0, RCS CM. Domain 102 returned 0x8. App Response Code 13
2008/10/30-11:18:24, [ZONE-1019], 40337,, ERROR, switch1, Transaction Commit failed. Reason code 3 (13) - "Sfc Was Rejected: Remote Switch Unable To Process".
SolutionAttempt zoning changes on an alternate switch in the same fabric switch5:admin> alicreate "test","2,10"
switch5:admin> zoneadd "prod","test" switch5:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Updating flash ... Success Now confirm this: switch5:admin> zoneshow prod zone: prod server1; storage1; storage2; test switch5:admin> alishow test alias: test 2,10 switch1:admin> alicreate "test2","2,11"
switch1:admin> zoneadd "prod","test2" switch1:admin> cfgsave You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled. Do you want to save Defined zoning configuration only? (yes, y, no, n): [no] yes Updating flash ... switch1:admin> Attachments This solution has no attachment |
||||||||||||||||
|