Solution Type  Problem Resolution Sure

Solution  1101429.1 :   Brocade Fabric switch: Unable to save Defined zoning configuration  


Related Items
  • Sun Storage SAN Foundation Software
  •  
  • Brocade 200E Switch
  •  
  • Brocade 24000 Director
  •  
  • Brocade 7500 Switch
  •  
  • Brocade 3200 Fabric Switch
  •  
  • Brocade 5000 Switch
  •  
  • Brocade 3800 Fabric Switch
  •  
  • Brocade 4900 Switch
  •  
  • Brocade 12000 Fabric Switch
  •  
  • Brocade 48000 Director
  •  
  • Brocade DCX-4S Backbone
  •  
  • Brocade 4100 Switch
  •  
  • Brocade 5100 Switch
  •  
  • Brocade DCX Backbone
  •  
  • Brocade 3850 Fabric Switch
  •  
  • Brocade DCX 8510 Backbone/Director
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun Storage SAN Foundation Software - Version 4.0 and later
Brocade 12000 Fabric Switch - Version Not Applicable to Not Applicable [Release N/A]
Brocade 200E Switch - Version Not Applicable to Not Applicable [Release N/A]
Brocade 24000 Director - Version Not Applicable to Not Applicable [Release N/A]
Brocade 3200 Fabric Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Attempts to save the current zoning configuration on a switch fail:

switch1:admin> alicreate "myalias","2,10"
switch1:admin> zoneadd "prod","myalias"
switch1:admin> cfgsave
You are about to save the Defined zoning configuration. This action will only save the changes on Defined configuration. Any changes made on the Effective configuration will not take effect until it is re-enabled.
Do you want to save Defined zoning configuration only?  (yes, y, no, n): [no] yes
Trans Save failed: Sfc Was Rejected: Remote Switch Unable To Process  <----------------FAILURE

 

Cause

Symptomatic messages from supportshow (errDump):

2008/10/30-11:18:24, [RCS-1006], 40334,, INFO, switch1, State 2, Application Zoning AD0, RCS CM. Domain 102 returned 0x8. App Response Code 13
2008/10/30-11:18:24, [ZONE-1019], 40337,, ERROR, switch1, Transaction Commit failed.  Reason code 3 (13) - "Sfc Was Rejected: Remote Switch Unable To Process".

 

Solution

Attempt zoning changes on an alternate switch in the same fabric

Login to an alternate switch (perhaps an edge switch) in the same fabric.
Now attempt to make some zoning changes

switch5:admin> alicreate "test","2,10"
switch5:admin> zoneadd "prod","test"
switch5:admin> cfgsave
You are about to save the Defined zoning configuration. This
action will only save the changes on Defined configuration.
Any changes made on the Effective configuration will not take effect until it is re-enabled.
Do you want to save Defined zoning configuration only?  (yes, y, no, n): [no] yes
Updating flash ...

Success
Now confirm this:

switch5:admin> zoneshow prod
 zone:  prod
                server1; storage1; storage2; test

switch5:admin> alishow test
 alias: test
                2,10

 


Now move back to the original switch where the problem was FIRST noticed and verify the success or failure of this workaround:

switch1:admin> alicreate "test2","2,11"
switch1:admin> zoneadd "prod","test2"
switch1:admin> cfgsave
You are about to save the Defined zoning configuration. This
action will only save the changes on Defined configuration.
Any changes made on the Effective configuration will not take effect until it is re-enabled.
Do you want to save Defined zoning configuration only?  (yes, y, no, n): [no] yes
Updating flash ...
switch1:admin>

 

fabstateShow or fabricLog -s may be used to further isolate this issue.
A specific sequence of events at the time of switch discovery may loop / timeout or fail

Product

Brocade Fabric OS v6.1.0
Brocade Fabric OS v6.1.0a
Brocade Fabric OS v6.1.0b
Brocade Fabric OS v6.1.0c
Brocade Fabric OS v6.2.0

Keywords
  
brocade, cfgsave, DCX, DEFECT000211542, Trans Save failed, Sfc Was Rejected, zoning, App Response Code 13

  
Change History

Date: 2010-04-19
User Name: 84789
Action: Reviewed
Comment: Reviewed & Updated