Solution Type Problem Resolution Sure Solution 1100574.1 : Verify-Topology -N Reports Wrong Information On Quarter Rac
In this Document
Created from <SR 3-1755464081> Applies to:Oracle Exadata Hardware - Version 11.1.0.6 and laterExadata X5-2 Hardware Information in this document applies to any platform. SymptomsOn Exadata Quarter Rack systems, running "verify-topology -n" reports wrong/misleading information for external switch: Running /opt/oracle.SupportTools/ibdiagtools/verify-topology -n... CauseThe incorrect syntax was used when running the command verify-topology on a Quarter Rack Exadata system since quarter racks will do not have a spine switch. SolutionThe syntax for the verify-topology command for a Quarter Rack should be ran as follows: ./verify-topology -t quarterrack
Output should look like: /opt/oracle.SupportTools/ibdiagtools/verify-topology -t quarterrack References<NOTE:1053498.1> - Network Diagnostics information for Oracle Database Machine EnvironmentsAttachments This solution has no attachment |
||||||||||||||||||
|