Asset ID: |
1-72-1020981.1 |
Update Date: | 2017-05-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1020981.1
:
Tape - CommVault Does Not See STK Libraries in Windows 2003 in the Device Manager When Attached to an Emulex 8gig HBA
Related Items |
- Sun StorageTek L180 Tape Library
- Sun StorageTek SL3000 Modular Library System
- Sun StorageTek SL500 Modular Library System
- Sun StorageTek SL8500 Modular Library System
- Sun StorageTek L700 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
|
PreviouslyPublishedAs
268468
Applies to:
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
All Platforms
Symptoms
CommVault does not see STK libraries in Windows 2003 in the device manger when attached to an Emulex 8 gig HBA.
Consider the following scenario:
- On a Windows Server 2003-based computer, you apply the 916048 hotfix, or you install Windows Server 2003 Service Pack 2 (SP2).
- Later, a request is made for SCSI bus 8 (the SCSI_MAXIMUM_BUSES value) on the computer.
In this scenario, the IOCTL_SCSI_GET_INQUIRY_DATA I/O control operation returns the following error:
STATUS_INVALID_DEVICE_REQUEST
Changes
{CHANGE}
Cause
{CAUSE}
Solution
Resolution
Microsoft Hotfix KB943545
Error returned by the IOCTL_SCSI_GET_INQUIRY_DATA operation on a Windows Server 2003-based computer: "STATUS_INVALID_DEVICE_REQUEST
Detailed information is located at the fix below:
Hotfix KB943545
This fix has been tested and verified in the Oracle/Sun lab.
Additional Information
Any of Sun's libraries connected with MS Server 2003, Emulex 8GB HBA, and Comm Vault 8.0 would see this issue.
Backup app: CommVault 8.0
OS : Windows 2003 64 bit.
HBA: HP branded Emulex card 8 gig (aj763a/ah403a) Driver 7.2.20.006 FW 1.00A12
Library: L700
Commvault 8.0, Windows 2003 Win2k3, Microsoft hotfix KB943545, HBA Emulex 8 gig, L700, L180, SL500, SL3000, SL8500, STATUS_INVALID_DEVICE_REQUEST