Solution Type  Problem Resolution Sure

Solution  1020628.1 :   STK L1400 - Router Discovery Delay Time gets Reset to 2 secs after Firmware Upgrade to 3.18.02  


Related Items
  • Sun StorageTek L1400 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  

PreviouslyPublishedAs
261968


Applies to:

Sun StorageTek L1400 Tape Library - Version All Versions and later
All Platforms

Symptoms

Router Discovery Delay Time gets Reset to 2 secs after Firmware Upgrade to 3.18.02.

Changes

{CHANGE}

Cause

{CAUSE}

Solution


Resolution
Solution expected in next firmware release

Relief/Workaround

Since the L1400 Library takes 8-9 mins to get initialized. The SN3000 router gets reset in 2 secs before the complete library is ready. So the fibre port connected to SAN switch or directly to server shows unavailable in the cfgadm output.

Login to the GUI of SN3000 router by connecting the laptop to ethernet port.The SN3000 router has the default ipaddress 1.1.1.1Steps to login & follow,the username password is mentioned below,Username – rootPassword – password1. Once you get the login, go to discovery tab on the left side of the windowand scroll down below and select the port settings.On the right side you will see Discovery delay option change the value to 600 secs 2. Go to discovery tab on the left side of the window and scroll down below and select the port settings further select FC port 0

Ports => ports menu => FC port 0

Set the value of Discovery mode to manual discovery only

 