![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1020595.1 : ACSLS - Error response from library handler, LH_E RR_REQUEST_INVALID during configuration of SL3000
PreviouslyPublishedAs 261328 Applies to:Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 7.0 and laterSun StorageTek SL3000 Modular Library System - Version All Versions and later All Platforms SymptomsError messages generated when running acsss_config for a non-partitioned library: Changes{CHANGE} Cause{CAUSE} SolutionThe host interface on the SL3000 library was set to non-partitioned SCSI and should be non-partitioned HLI (host LMU interface). Attachments This solution has no attachment |
||||||||||||
|