![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1019760.1 : SL3000 Drive Auto Cleaning Not Working via ACSLS or HSC
PreviouslyPublishedAs 245266 Applies to:Sun StorageTek Host Software Component (HSC) for MVS and z/OS - Version 6.2 and laterSun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 7.2 and later Sun StorageTek SL3000 Modular Library System - Version All Versions and later IBM z/OS on System z SymptomsAuto cleaning not working CauseWhen automatic cleaning is enabled via ACSLS or HSC, they will automatically mount a cleaning tape on the next mount when they receive a "drive needs cleaning" message from the library after a dismount. However, if automatic cleaning is enabled at the SL3000 library level via SL Console, the library is the one doing the automated cleaning. When the library does automated cleaning, it does NOT send the drive needs cleaning message to ACSLS and HSC. ACSLS and HSC will never know that the drive needs to be cleaned. The library will try to mount a cleaning cartridge from one of its system cells to clean the drive before sending the host the dismount response. There are no cleaning media in the system cells because they are instead in normal library cells accessible by HSC or ACSLS. SolutionIf ACSLS or HSC automated cleaning is on, but drives are not being cleaned, check if the library also has auto cleaning turned on. If auto cleaning is enabled at the library, turn it off via SL Console (SLC). To do this, use either the SL Console or the Operator Panel:
See if Auto Cleaning is enabled for this partition (or "Partition 1 or None").
Attachments This solution has no attachment |
||||||||||||
|