![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1019490.1 : KMS - KMA Station BIOS Issue
PreviouslyPublishedAs 240093 Oracle Confidential PARTNER - Available to partners (SUN). Reason: Confidential for Partners and Oracle Support personnel Applies to:Oracle Key Manager - Version 1.1.0 and laterAll Platforms Checked for relevance on 15-June-2011. SymptomsKMA 2.0 systems shipped prior to July 3, 2008 may have been built with old and incorrect version of BIOS and ELOM code. So far, only one such system has been found in the field. Changes{CHANGE} Cause{CAUSE} SolutionResolution Attachments This solution has no attachment |
||||||||||||
|