![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1018926.1 : Gigabit port on Chromis/N2000 switch fails to link up with Sun gigabit interface cards
PreviouslyPublishedAs 230775 Symptoms Link fails to establish when connecting the SUN system ce, ge and similar gigabit cards to the N2000 gigabit ports Resolution The reason for this is that SUN defaults to autonegotiation and the N2000 defaults to 1000M full duplex forced. There are several ways to correct this parameter mismatch with the prefered method being autonegotiation on both the N2000 switch and the SUN system. 1) Change the default settings on the N2000 switch from 1000M full duplex forced to autonegotiation. (prefered method) Using the N2000 GUI interface: a) select port list b) check the boxes that are next to gigEthernet c) click modify d) change the default 1000M to auto e) click submit f) attempt to establish link g) if link is now established, click SaveCfg Using the N2000 CLI interface: a) Enter enable mode sun.250> enable b) Enter configure mode sun.250# configure c) Configure the port for auto negotiate sun.250(config)# port ifName eth.1.1 phySpeed auto d) Save the configuration sun.250(config)# saveCfg 2) Change the default on the SUN server side from autonegotiation to 1000M full duplex forced so that this will now match the settings on the N2000. Operational mode parameters on Sun Solaris can be changed via ndd -set /dev/ce or editing ce.conf, see troubleshooting in Infodoc 41665 and Infodoc 72033 for details Note: In accordance with IEEE 802.3 Sun recommends to use autonegotiated operational modes. This is the default. Product Sun Secure Application Switch - N2000 Series N2000, autonegotiation, link, mismatch Previously Published As 81353 Change History Date: 2005-04-29 User Name: 25440 Action: Approved Comment: Publishing. Version: 4 Date: 2005-04-29 User Name: 25440 Action: Accept Comment: Version: 0 Date: 2005-04-28 User Name: 117923 Action: Approved Comment: The document is technically correct and I approve this for publication. Version: 0 Product_uuid 0c270f89-53b6-11d9-a841-080020a9ed93|Secure Application Switches Attachments This solution has no attachment |
||||||||||||
|