![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1017586.1 : Sun Fire V210/V240/Netra 240 Server: System Hangs After Completing POST
PreviouslyPublishedAs 228741 Applies to:Sun Netra 240 (DC) Server - Version Not Applicable and laterSun Fire V210 Server - Version Not Applicable and later Sun Fire V240 Server - Version Not Applicable and later All Platforms SymptomsThe Sun Fire[TM] V240 system passes POST diagnostic but then hangs: Keyswitch set to diagnostic position. (#)OBP 4.11.4 2003/07/23 08:04 Sun Fire V210/V240,Netra 240 Clearing TLBs Power-On Reset Executing Power On SelfTest 0>@(#) Sun Fire[TM] V210/V240,Netra[TM] 240 POST 4.11.4 2003/07/23 11:42 /export/common-source/firmware_re/post/post-build-4.11.4/Fiesta/enxs/inte grated (firmware_re) 0>Hard Powerup RST thru SW 0>CPUs present in system: 0 1 0>OBP->POST Call with %o0=00000000.01002000. 0>Diag level set to MIN. 0>MFG scrpt mode set to NONE 0>I/O port set to TTYA. 0> 0>Start selftest... . . . text removed for brevity . CPU 0 Bank 0 base 0 size 1024 MB CPU 1 Bank 0 base 1000000000 size 1024 MB Probing /pci@1d,700000 Device 2 network network Probing /pci@1f,700000 Device 2 network network Probing /pci@1e,600000 Device 6 pmu i2c gpio Probing /pci@1e,600000 Device a usb Probing /pci@1e,600000 Device d ide disk cdrom Probing /pci@1e,600000 Device 2 Nothing there Probing /pci@1e,600000 Device 3 Nothing there Probing /pci@1c,600000 Device 2 scsi disk tape scsi disk tape Probing /pci@1c,600000 Device 1 Nothing there Probing /pci@1d,700000 Device 1 Nothing there prompt, but communication with ALOM is possible and all indications from the "showenvironment" command are normal. CauseNVRAM needs to be reset. SolutionResolution In case of verbosity=normal, one of OBP parameter, the console message will be like the following. 0>Copyright Sun Microsystems, Inc. All rights reserved SUN PROPRIETARY/CONFIDENTIAL. Use is subject to license terms. 0>OBP->POST Call with %o0=00000800.01012000. 0>Diag level set to MIN. 0>Verbosity level set to NORMAL. 0>Start Selftest..... 0>CPUs present in system: 0 1 0>Test CPU(s)....Done 0>Interrupt Crosscall....Done 0>Init Memory....Done 0>PLL Reset....Done 0>Init Memory....Done 0>Test Memory....Done 0>IO-Bridge Tests....Done 0>INFO: 0> POST Passed all devices. 0> 0>POST: Return to OBP. SC Alert: Host System has Reset Configuring system memory & CPU(s) Probing system devices Probing memory Probing I/O buses Product Sun Fire V240 Server Sun Fire V210 Server Netra 240 Server Attachments This solution has no attachment |
||||||||||||
|