Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1017051.1
Update Date:2017-08-30
Keywords:

Solution Type  Problem Resolution Sure

Solution  1017051.1 :   9310/4410/L5510 - Door interlock open  


Related Items
  • Sun StorageTek 4410 Tape Library
  •  
  • Sun StorageTek 9310 Automated Cartridge System
  •  
  • Sun StorageTek L5500 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  
  • _Old GCS Categories>Sun Microsystems>Storage - Tape>Libraries - 9300-Series
  •  

PreviouslyPublishedAs
227724


Applies to:

Sun StorageTek 4410 Tape Library - Version Not Applicable and later
Sun StorageTek 9310 Automated Cartridge System - Version Not Applicable and later
Sun StorageTek L5500 Tape Library - Version Not Applicable and later
All Platforms

Symptoms

Door interlock open.
LSM will not initialize. IPL procedes to IPL COMPLETE message, then SERVICE REQUIRED indicator illuminates with SEE EVENT LOG message. Event log indicates that the door interlock circuit is open.

Changes

{CHANGE}

Cause

The main door interlock switch actuator was initially mispositioned during install and slightly bent the switch mounting bracket when the door was closed. When the switch mounting bracket is slightly bent, the actuator will not cause the switch to actuate, even if it appears to be properly adjusted.

Solution

Resolution
Bend the main door interlock switch mounting bracket back to the correct angle.