Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1016849.1
Update Date:2018-04-10
Keywords:

Solution Type  Problem Resolution Sure

Solution  1016849.1 :   SL500 - Redundant Power Supply Turned Off in DEM, Result Code 8003  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  

PreviouslyPublishedAs
227171


Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
All Platforms

Symptoms

Symptoms
LED on one of the power supplies will turn off and the service required LED will begin to Flash
Power supply failure
Power supply error in the log
RC8003
Error 8003

 

Changes

{CHANGE}

Cause

Redundant power supply installed in DEM. When the voltage on the 3.3V line of the 2 supplies is far enough apart it can cause one of the supplies to be shut down

All the RLE - PN 313907406 and older have been purged from stock.

Solution

Prior to replacement of the RLE card for this problem, a new power supply should be tried.  7046237 [C] 450 Watt Power Supply.

If the new power supply also fails then proceed to replacing the RLE card that the failing power supply plugs into.  Use PN 313907408 level or higher.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback