Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1015775.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1015775.1 :   SL500 - Door Open Button Fails to Operate After Park Command is Issued via CLI  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  

PreviouslyPublishedAs
224497


Applies to:

Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
All Platforms

Symptoms

Door open button fails to operate.
CAP button fails to operate.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

The intent of the "Park" command is to position the robot such that is can be removed. A reboot is required to recover once the command is issued.
It is not a requirement to recover from the command as the purpose is to remove/replace the robot, which requires a reboot anyway.

"Park" Command-

Parks the robot in the home position inside the robotics unit so the robot can be removed. You must reboot the library to return it to active status by either power cycling the library or opening and closing the front door.

Note: the robotics unit MUST initialize or it will be out of alignment by two array cells.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.