![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1015775.1 : SL500 - Door Open Button Fails to Operate After Park Command is Issued via CLI
PreviouslyPublishedAs 224497 Applies to:Sun StorageTek SL500 Modular Library System - Version Not Applicable and laterAll Platforms SymptomsDoor open button fails to operate. Changes{CHANGE} Cause{CAUSE} SolutionThe intent of the "Park" command is to position the robot such that is can be removed. A reboot is required to recover once the command is issued. "Park" Command- Parks the robot in the home position inside the robotics unit so the robot can be removed. You must reboot the library to return it to active status by either power cycling the library or opening and closing the front door. Note: the robotics unit MUST initialize or it will be out of alignment by two array cells. Attachments This solution has no attachment |
||||||||||||
|