Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1015447.1
Update Date:2017-09-25
Keywords:

Solution Type  Problem Resolution Sure

Solution  1015447.1 :   L180/700/1400 - All Drives Positions in Drive Tower Report None Functional  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  

PreviouslyPublishedAs
223727


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential information provided to Oracle and Partner Service Personnel

Applies to:

Sun StorageTek L700 Tape Library - Version Not Applicable and later
Sun StorageTek L180 Tape Library - Version Not Applicable and later
Sun StorageTek L1400 Tape Library - Version Not Applicable and later
All Platforms

Symptoms

FSC3E0B
FSC3E0C
Drives not functional

Changes

{CHANGE}

Cause

{CAUSE}

Solution

All Drives Positions in Drive Tower Report None Functional:
1. Re-ipl drive

2. Run diags on drives from library.

3. If drive is still not functional, move to tower 1 or to working slot if possible.

4. If re-ipling drive brings it online to L700 op panel, replace hand assembly.

5. It is possible to swap tower 0 connection on MPC card with tower 1.
(Note: Drives must be brought online and ready for this to work)

6. Run diags from library:

a. If tower connection 0 is still bad, replace MPC card.

b. If tower 1 is bad, replace tower.




Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback